Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Sci Rep ; 13(1): 22660, 2023 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-38114733

RESUMO

The aim of this study was to determine tissue-specific blood perfusion impairment of the cervical cord above the compression site in patients with degenerative cervical myelopathy (DCM) using intravoxel incoherent motion (IVIM) imaging. A quantitative MRI protocol, including structural and IVIM imaging, was conducted in healthy controls and patients. In patients, T2-weighted scans were acquired to quantify intramedullary signal changes, the maximal canal compromise, and the maximal cord compression. T2*-weighted MRI and IVIM were applied in all participants in the cervical cord (covering C1-C3 levels) to determine white matter (WM) and grey matter (GM) cross-sectional areas (as a marker of atrophy), and tissue-specific perfusion indices, respectively. IVIM imaging resulted in microvascular volume fraction ([Formula: see text]), blood velocity ([Formula: see text]), and blood flow ([Formula: see text]) indices. DCM patients additionally underwent a standard neurological clinical assessment. Regression analysis assessed associations between perfusion parameters, clinical outcome measures, and remote spinal cord atrophy. Twenty-nine DCM patients and 30 healthy controls were enrolled in the study. At the level of stenosis, 11 patients showed focal radiological evidence of cervical myelopathy. Above the stenosis level, cord atrophy was observed in the WM (- 9.3%; p = 0.005) and GM (- 6.3%; p = 0.008) in patients compared to healthy controls. Blood velocity (BV) and blood flow (BF) indices were decreased in the ventral horns of the GM (BV: - 20.1%, p = 0.0009; BF: - 28.2%, p = 0.0008), in the ventral funiculi (BV: - 18.2%, p = 0.01; BF: - 21.5%, p = 0.04) and lateral funiculi (BV: - 8.5%, p = 0.03; BF: - 16.5%, p = 0.03) of the WM, across C1-C3 levels. A decrease in microvascular volume fraction was associated with GM atrophy (R = 0.46, p = 0.02). This study demonstrates tissue-specific cervical perfusion impairment rostral to the compression site in DCM patients. IVIM indices are sensitive to remote perfusion changes in the cervical cord in DCM and may serve as neuroimaging biomarkers of hemodynamic impairment in future studies. The association between perfusion impairment and cervical cord atrophy indicates that changes in hemodynamics caused by compression may contribute to the neurodegenerative processes in DCM.


Assuntos
Medula Cervical , Doenças Musculoesqueléticas , Compressão da Medula Espinal , Doenças da Medula Espinal , Humanos , Constrição Patológica/patologia , Doenças da Medula Espinal/diagnóstico por imagem , Doenças da Medula Espinal/patologia , Compressão da Medula Espinal/diagnóstico por imagem , Compressão da Medula Espinal/patologia , Imageamento por Ressonância Magnética/métodos , Medula Cervical/diagnóstico por imagem , Medula Cervical/patologia , Perfusão , Doenças Musculoesqueléticas/patologia , Atrofia/patologia , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/patologia
2.
Front Neurol ; 14: 1120227, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37251221

RESUMO

Objective: Preclinical studies have shown that cognitive impairments following spinal cord injury (SCI), such as impaired spatial memory, are linked to inflammation, neurodegeneration, and reduced neurogenesis in the right hippocampus. This cross-sectional study aims to characterize metabolic and macrostructural changes in the right hippocampus and their association to cognitive function in traumatic SCI patients. Methods: Within this cross-sectional study, cognitive function was assessed in 28 chronic traumatic SCI patients and 18 age-, sex-, and education-matched healthy controls by a visuospatial and verbal memory test. A magnetic resonance spectroscopy (MRS) and structural MRI protocol was performed in the right hippocampus of both groups to quantify metabolic concentrations and hippocampal volume, respectively. Group comparisons investigated changes between SCI patients and healthy controls and correlation analyses investigated their relationship to memory performance. Results: Memory performance was similar in SCI patients and healthy controls. The quality of the recorded MR spectra was excellent in comparison to the best-practice reports for the hippocampus. Metabolite concentrations and volume of the hippocampus measured based on MRS and MRI were not different between two groups. Memory performance in SCI patients and healthy controls was not correlated with metabolic or structural measures. Conclusion: This study suggests that the hippocampus may not be pathologically affected at a functional, metabolic, and macrostructural level in chronic SCI. This points toward the absence of significant and clinically relevant trauma-induced neurodegeneration in the hippocampus.

3.
Neuroimage ; 271: 120046, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36948280

RESUMO

Short MRI acquisition time, high signal-to-noise ratio, and high reliability are crucial for image quality when scanning healthy volunteers and patients. Cross-sectional cervical cord area (CSA) has been suggested as a marker of neurodegeneration and potential outcome measure in clinical trials and is conventionally measured on T1-weigthed 3D Magnetization Prepared Rapid Acquisition Gradient-Echo (MPRAGE) images. This study aims to reduce the acquisition time for the comprehensive assessment of the spinal cord, which is typically based on MPRAGE for morphometry and multi-parameter mapping (MPM) for microstructure. The MPRAGE is replaced by a synthetic T1-w MRI (synT1-w) estimated from the MPM, in order to measure CSA. SynT1-w images were reconstructed using the MPRAGE signal equation based on quantitative maps of proton density (PD), longitudinal (R1) and effective transverse (R2*) relaxation rates. The reliability of CSA measurements from synT1-w images was determined within a multi-center test-retest study format and validated against acquired MPRAGE scans by assessing the agreement between both methods. The response to pathological changes was tested by longitudinally measuring spinal cord atrophy following spinal cord injury (SCI) for synT1-w and MPRAGE using linear mixed effect models. CSA measurements based on the synT1-w MRI showed high intra-site (Coefficient of variation [CoV]: 1.43% to 2.71%) and inter-site repeatability (CoV: 2.90% to 5.76%), and only a minor deviation of -1.65 mm2 compared to MPRAGE. Crucially, by assessing atrophy rates and by comparing SCI patients with healthy controls longitudinally, differences between synT1-w and MPRAGE were negligible. These results demonstrate that reliable estimates of CSA can be obtained from synT1-w images, thereby reducing scan time significantly.


Assuntos
Traumatismos da Medula Espinal , Medula Espinal , Humanos , Reprodutibilidade dos Testes , Estudos Transversais , Medula Espinal/patologia , Imageamento por Ressonância Magnética/métodos , Traumatismos da Medula Espinal/patologia , Atrofia/patologia
4.
Neuroimage ; 264: 119751, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36384206

RESUMO

MRI based multicenter studies which target neurological pathologies affecting the spinal cord and brain - including spinal cord injury (SCI) - require standardized acquisition protocols and image processing methods. We have optimized and applied a multi-parameter mapping (MPM) protocol that simultaneously covers the brain and the cervical cord within a traveling heads study across six clinical centers (Leutritz et al., 2020). The MPM protocol includes quantitative maps (magnetization transfer saturation (MT), proton density (PD), longitudinal (R1), and effective transverse (R2*) relaxation rates) sensitive to myelination, water content, iron concentration, and morphometric measures, such as cross-sectional cord area. Previously, we assessed the repeatability and reproducibility of the brain MPM data acquired in the five healthy participants who underwent two scan-rescans (Leutritz et al., 2020). This study focuses on the cervical cord MPM data derived from the same acquisitions to determine its repeatability and reproducibility in the cervical cord. MPM matrices of the cervical cord were generated and processed using the hMRI and the spinal cord toolbox. To determine reliability of the cervical MPM data, the intra-site (i.e., scan-rescan) coefficient of variation (CoV), inter-site CoV, and bias within region of interests (C1, C2 and C3 levels) were determined. The range of the mean intra- and inter-site CoV of MT, R1 and PD was between 2.5% and 12%, and between 1.1% and 4.0% for the morphometric measures. In conclusion, the cervical MPM data showed a high repeatability and reproducibility for key imaging biomarkers and hence can be employed as a standardized tool in multi-center studies, including clinical trials.


Assuntos
Medula Cervical , Humanos , Medula Cervical/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Transversais , Imageamento por Ressonância Magnética/métodos , Medula Espinal/patologia
5.
J Neuroimaging ; 32(6): 1121-1133, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35962464

RESUMO

BACKGROUND AND PURPOSE: The timing of decision-making for a surgical intervention in patients with mild degenerative cervical myelopathy (DCM) is challenging. Spinal cord motion phase contrast MRI (PC-MRI) measurements can reveal the extent of dynamic mechanical strain on the spinal cord to potentially identify high-risk patients. This study aims to determine the comparability of axial and sagittal PC-MRI measurements of spinal cord motion with the prospect of improving the clinical workup. METHODS: Sixty-four DCM patients underwent a PC-MRI scan assessing spinal cord motion. The agreement of axial and sagittal measurements was determined by means of intraclass correlation coefficients (ICCs) and Bland-Altman analyses. RESULTS: The comparability of axial and sagittal PC-MRI measurements was good to excellent at all cervical levels (ICCs motion amplitude: .810-.940; p < .001). Significant differences between axial and sagittal amplitude values could be found at segments C3 and C4, while its magnitude was low (C3: 0.07 ± 0.19 cm/second; C4: -0.12 ± 0.30 cm/second). Bland-Altman analysis showed a good agreement between axial and sagittal PC-MRI scans (coefficients of repeatability: minimum -0.23 cm/second at C2; maximum -0.58 cm/second at C4). Subgroup analysis regarding anatomic conditions (stenotic vs. nonstenotic segments) and different velocity encoding (2 vs. 3 cm/second) showed comparable results. CONCLUSIONS: This study demonstrates good comparability between axial and sagittal spinal cord motion measurements in DCM patients. To this end, axial and sagittal PC-MRI are both accurate and sensitive in detecting pathologic cord motion. Therefore, such measures could identify high-risk patients and improve clinical decision-making (ie, timing of decompression).


Assuntos
Compressão da Medula Espinal , Doenças da Medula Espinal , Humanos , Vértebras Cervicais/diagnóstico por imagem , Doenças da Medula Espinal/diagnóstico por imagem , Doenças da Medula Espinal/patologia , Medula Espinal , Pescoço , Imageamento por Ressonância Magnética/métodos , Compressão da Medula Espinal/diagnóstico por imagem
6.
Magn Reson Med ; 88(2): 849-859, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35476875

RESUMO

PURPOSE: Spinal cord gray-matter imaging is valuable for a number of applications, but remains challenging. The purpose of this work was to compare various MRI protocols at 1.5 T, 3 T, and 7 T for visualizing the gray matter. METHODS: In vivo data of the cervical spinal cord were collected from nine different imaging centers. Data processing consisted of automatically segmenting the spinal cord and its gray matter and co-registering back-to-back scans. We computed the SNR using two methods (SNR_single using a single scan and SNR_diff using the difference between back-to-back scans) and the white/gray matter contrast-to-noise ratio per unit time. Synthetic phantom data were generated to evaluate the metrics performance. Experienced radiologists qualitatively scored the images. We ran the same processing on an open-access multicenter data set of the spinal cord MRI (N = 267 participants). RESULTS: Qualitative assessments indicated comparable image quality for 3T and 7T scans. Spatial resolution was higher at higher field strength, and image quality at 1.5 T was found to be moderate to low. The proposed quantitative metrics were found to be robust to underlying changes to the SNR and contrast; however, the SNR_single method lacked accuracy when there were excessive partial-volume effects. CONCLUSION: We propose quality assessment criteria and metrics for gray-matter visualization and apply them to different protocols. The proposed criteria and metrics, the analyzed protocols, and our open-source code can serve as a benchmark for future optimization of spinal cord gray-matter imaging protocols.


Assuntos
Medula Cervical , Substância Branca , Substância Cinzenta/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Estudos Multicêntricos como Assunto , Medula Espinal/diagnóstico por imagem , Substância Branca/diagnóstico por imagem
7.
Clin EEG Neurosci ; : 15500594221089366, 2022 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-35360976

RESUMO

Previous studies indicated that heroin abuse would result in abnormal functional organization of the brain. However, studies of heroin abuse- related brain dysfunction are scarce. The purpose of the present study was to investigate heroin effects on brain function by studying relationships between Electroencephalograph (EEG) spectral power and heroin abuse. The resting EEG signals were acquired from 15 male heroin dependent group and 15 male control group. The differences in the EEG components of each group were evaluated using the statistical Mann-Whitney examination and Davis Bouldin Index. The results show that heroin dependent group has an attenuated relative beta-2 power compared with other EEG frequency sub bands. Nevertheless, the results indicate heroin dependent group have an increase of power spectrum density for theta at all locations, as well as delta in the temporal, frontal and central areas compared with control group. Compared to control group, the heroin dependent group decreased its spectral power more than the control group in all three alpha bands. The present findings using the Davis Bouldin Index provide evidence that alpha-3 band in the FZ channel is more affected by heroin abuse than other frequency sub bands.

8.
J Neurotrauma ; 39(9-10): 639-650, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35018824

RESUMO

This study compares remote neurodegenerative changes caudal to a cervical injury in degenerative cervical myelopathy (DCM; i.e., non-traumatic) and incomplete traumatic spinal cord injury (tSCI) patients, using magnetic resonance imaging (MRI)-based tissue area measurements and diffusion tensor imaging (DTI). Eighteen mild-to-moderate DCM patients with sensory impairments (modified Japanese Orthopedic score: 16.2 ± 1.9), 14 incomplete tetraplegic tSCI patients (American Spinal Injury Association Impairment Scale C and D), and 20 healthy controls were recruited. All participants received DTI and T2*-weighted scans in the lumbosacral enlargement (caudal to injury) and at C2/C3 (rostral to injury). MRI readouts included DTI metrics in the white matter (WM) columns and cross-sectional WM and gray matter area. One-way analysis of variance with Tukey's post hoc comparison (p < 0.05) was used to assess group differences. In the lumbosacral enlargement, compared with DCM, tSCI patients exhibited decreased fractional anisotropy in the lateral (tSCI vs. DCM, -11.9%, p = 0.007) and ventral WM column (-8.0%, p = 0.021), and showed a trend toward lower values in the dorsal column (-8.9%, p = 0.068). At C2/C3, compared with controls, fractional anisotropy was lower in both groups in the dorsal (DCM vs. controls, -7.9%, p = 0.024; tSCI vs. controls, -10.0%, p = 0.007) and in the lateral column (DCM: -6.2%, p = 0.039; tSCI: -13.3%, p < 0.001), while tSCI patients had lower fractional anisotropy than DCM patients in the lateral column (-7.6%, p = 0.029). WM areas were not different between patient groups but were lower compared with controls in the lumbosacral enlargement (DCM: -16.9%, p < 0.001; tSCI: -10.5%, p = 0.043) and at C2/C3 (DCM: -16.0%, p < 0.001; tSCI: -18.1%, p < 0.001). In conclusion, mild-to-moderate DCM and incomplete tSCI lead to similar degree of degeneration of the dorsal and lateral columns at C2/C3, but tSCI results in more widespread white matter damage in the lumbosacral enlargement. These remote changes are likely to contribute to the patients' impairment and recovery. DTI is a sensitive tool to assess remote pathological changes in DCM and tSCI patients.


Assuntos
Traumatismos da Medula Espinal , Traumatismos da Coluna Vertebral , Estudos Transversais , Imagem de Tensor de Difusão/métodos , Humanos , Medula Espinal , Traumatismos da Medula Espinal/diagnóstico por imagem
9.
Front Med (Lausanne) ; 8: 697055, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34447762

RESUMO

Background: Kidney perfusion and oxygenation are two important determinants of kidney graft function. In kidney transplantation, repeated graft hypoperfusion may occur during hip flexion, for example in the sitting position, due to the progressive development of fibrotic tissue around iliac arteries. The aim of this study was to assess the changes in oxygenation and perfusion of kidney grafts during hip flexion and extension using a new functional magnetic resonance imaging (fMRI) protocol. Methods: Nineteen kidney graft recipients prospectively underwent MRI on a 3T scanner including diffusion-weighted, blood oxygenation level dependent (BOLD), and arterial spin labeling sequences in hip positions 0° and >90° before and after intravenous administration of 20 mg furosemide. Results: Unexpectedly, graft perfusion values were significantly higher in flexed compared to neutral hip position. Main diffusion-derived parameters were not affected by hip position. BOLD-derived cortico-medullary R2* ratio was significantly modified during hip flexion suggesting an intrarenal redistribution of the oxygenation in favor of the medulla and to the detriment of the cortex. Furthermore, the increase in medullary oxygenation induced by furosemide was significantly blunted during hip flexion (p < 0.001). Conclusion: Hip flexion has an acute impact on perfusion and tissue oxygenation in kidney grafts. Whether these position-dependent changes affect the long-term function and outcome of kidney transplants needs further investigation.

10.
J Neurotrauma ; 38(21): 2978-2987, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34238034

RESUMO

This study aims to determine tissue-specific neurodegeneration across the spinal cord in patients with mild-moderate degenerative cervical myelopathy (DCM). Twenty-four mild-moderate DCM and 24 healthy subjects were recruited. In patients, a T2-weighted scan was acquired at the compression site, whereas in all participants a T2*-weighted and diffusion-weighted scan was acquired at the cervical level (C2-C3) and in the lumbar enlargement (i.e., rostral and caudal to the site of compression). We quantified intramedullary signal changes, maximal canal and cord compression, white (WM) and gray matter (GM) atrophy, and microstructural indices from diffusion-weighted scans. All patients underwent clinical (modified Japanese Orthopaedic Association; mJOA) and electrophysiological assessments. Regression analysis assessed associations between magnetic resonance imaging (MRI) readouts and electrophysiological and clinical outcomes. Twenty patients were classified with mild and 4 with moderate DCM using the mJOA scale. The most frequent site of compression was at the C5-C6 level, with maximum cord compression of 38.73% ± 11.57%. Ten patients showed imaging evidence of cervical myelopathy. In the cervical cord, WM and GM atrophy and WM microstructural changes were evident, whereas in the lumbar cord only WM showed atrophy and microstructural changes. Remote cervical cord WM microstructural changes were pronounced in patients with radiological myelopathy and associated with impaired electrophysiology. Lumbar cord WM atrophy was associated with lower limb sensory impairments. In conclusion, tissue-specific neurodegeneration revealed by quantitative MRI is already apparent across the spinal cord in mild-moderate DCM before the onset of severe clinical impairments. WM microstructural changes are particularly sensitive to remote pathologically and clinically eloquent changes in DCM.


Assuntos
Medula Cervical/patologia , Substância Cinzenta/patologia , Doenças da Medula Espinal/complicações , Doenças da Medula Espinal/patologia , Substância Branca/patologia , Adulto , Idoso , Atrofia , Estudos de Casos e Controles , Vértebras Cervicais , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade
11.
Hum Brain Mapp ; 42(1): 220-232, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32991031

RESUMO

To validate a simultaneous analysis tool for the brain and cervical cord embedded in the statistical parametric mapping (SPM) framework, we compared trauma-induced macro- and microstructural changes in spinal cord injury (SCI) patients to controls. The findings were compared with results obtained from existing processing tools that assess the brain and spinal cord separately. A probabilistic brain-spinal cord template (BSC) was generated using a generative semi-supervised modelling approach. The template was incorporated into the pre-processing pipeline of voxel-based morphometry and voxel-based quantification analyses in SPM. This approach was validated on T1-weighted scans and multiparameter maps, by assessing trauma-induced changes in SCI patients relative to controls and comparing the findings with the outcome from existing analytical tools. Consistency of the MRI measures was assessed using intraclass correlation coefficients (ICC). The SPM approach using the BSC template revealed trauma-induced changes across the sensorimotor system in the cord and brain in SCI patients. These changes were confirmed with established approaches covering brain or cord, separately. The ICC in the brain was high within regions of interest, such as the sensorimotor cortices, corticospinal tracts and thalamus. The simultaneous voxel-wise analysis of brain and cervical spinal cord was performed in a unique SPM-based framework incorporating pre-processing and statistical analysis in the same environment. Validation based on a SCI cohort demonstrated that the new processing approach based on the brain and cord is comparable to available processing tools, while offering the advantage of performing the analysis simultaneously across the neuraxis.


Assuntos
Encéfalo/diagnóstico por imagem , Medula Cervical/diagnóstico por imagem , Neuroimagem/métodos , Traumatismos da Medula Espinal/diagnóstico por imagem , Adulto , Encéfalo/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Neuroimagem/normas , Tratos Piramidais/diagnóstico por imagem , Tratos Piramidais/patologia , Córtex Sensório-Motor/diagnóstico por imagem , Córtex Sensório-Motor/patologia , Traumatismos da Medula Espinal/patologia , Tálamo/diagnóstico por imagem , Tálamo/patologia
12.
Hum Brain Mapp ; 41(15): 4232-4247, 2020 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-32639104

RESUMO

Multicenter clinical and quantitative magnetic resonance imaging (qMRI) studies require a high degree of reproducibility across different sites and scanner manufacturers, as well as time points. We therefore implemented a multiparameter mapping (MPM) protocol based on vendor's product sequences and demonstrate its repeatability and reproducibility for whole-brain coverage. Within ~20 min, four MPM metrics (magnetization transfer saturation [MT], proton density [PD], longitudinal [R1], and effective transverse [R2*] relaxation rates) were measured using an optimized 1 mm isotropic resolution protocol on six 3 T MRI scanners from two different vendors. The same five healthy participants underwent two scanning sessions, on the same scanner, at each site. MPM metrics were calculated using the hMRI-toolbox. To account for different MT pulses used by each vendor, we linearly scaled the MT values to harmonize them across vendors. To determine longitudinal repeatability and inter-site comparability, the intra-site (i.e., scan-rescan experiment) coefficient of variation (CoV), inter-site CoV, and bias across sites were estimated. For MT, R1, and PD, the intra- and inter-site CoV was between 4 and 10% across sites and scan time points for intracranial gray and white matter. A higher intra-site CoV (16%) was observed in R2* maps. The inter-site bias was below 5% for all parameters. In conclusion, the MPM protocol yielded reliable quantitative maps at high resolution with a short acquisition time. The high reproducibility of MPM metrics across sites and scan time points combined with its tissue microstructure sensitivity facilitates longitudinal multicenter imaging studies targeting microstructural changes, for example, as a quantitative MRI biomarker for interventional clinical trials.


Assuntos
Mapeamento Encefálico/normas , Processamento de Imagem Assistida por Computador/normas , Imageamento por Ressonância Magnética/normas , Adulto , Mapeamento Encefálico/instrumentação , Mapeamento Encefálico/métodos , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Masculino , Reprodutibilidade dos Testes
13.
Neuroimage Clin ; 26: 102221, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32145681

RESUMO

OBJECTIVE: To quantify neurodegenerative changes along the cervical spinal cord rostral to a spinal cord injury (SCI) by means of quantitative MRI (qMRI) and to determine its relationship with clinical impairment. METHODS: Thirty chronic SCI patients (15 tetraplegics and 15 paraplegics) and 23 healthy controls underwent a high-resolution T1-weighted and myelin-sensitive magnetization transfer (MT) MRI. We assessed macro- and microstructural changes along the cervical cord from levels C1 to C4, calculating cross-sectional spinal cord area, its anterior-posterior and left-right width and myelin content (i.e. MT). Regression analysis determined associations between qMRI parameters and clinical impairment. RESULTS: In SCI patients, cord area decreased by 2.67 mm2 (p = 0.004) and left-right width decreased by 0.35 mm (p = 0.002) per cervical cord level in the caudal direction when compared to the healthy controls. This gradient of neurodegeneration was greater in tetraplegic than paraplegics in the cross-sectional cervical cord area (by 3.28 mm2, p = 0.011), left-right width (by 0.36 mm, p = 0.03), and mean cord MT (by 0.13%, p = 0.04), but independant of lesion severity (p > 0.05). Higher lesion level was associated with greater magnitudes of neurodegeneration. Greater loss in myelin content in the dorsal columns and spinothalamic tract was associated with worse light touch (p = 0.016) and pin prick score (p = 0.024), respectively. CONCLUSIONS: A gradient of neurodegeneration is evident in the cervical cord remote from a SCI. Tract-specific associations with appropriate clinical outcomes highlight that remote neurodegenerative changes are clinically eloquent. Monitoring the neurodegenerative gradient could be used to track treatment effects of regenerative and neuroprotective agents, both in trials targeting cervical and thoracic SCI patients.


Assuntos
Medula Cervical/patologia , Degeneração Neural/patologia , Traumatismos da Medula Espinal/patologia , Adulto , Idoso , Medula Cervical/diagnóstico por imagem , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Degeneração Neural/diagnóstico por imagem , Traumatismos da Medula Espinal/diagnóstico por imagem , Adulto Jovem
14.
Eur Urol Focus ; 6(5): 826-837, 2020 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-32122815

RESUMO

Neuroimaging allows in vivo visualization of neuronal structures/processes to assess their involvement in bodily functions. This is particularly valuable for the assessment of complex, multilevel neuronal controlled functions, such as urine storage and micturition. Using positron emission tomography or functional magnetic resonance imaging, significant alterations of supraspinal lower urinary tract (LUT) control have been described in patients with neurogenic LUT dysfunction due to spinal cord injury, Parkinson's disease, and multiple sclerosis. Severity of such alterations often correlates with symptom/dysfunction severity, both of which could be partly mitigated by therapeutic interventions. However, the overall evidence and study quality are presently very limited, and a multidisciplinary approach will be required to achieve clinical relevance in the long term. PATIENT SUMMARY: We reviewed the findings of neuroimaging studies in patients with bladder dysfunction due to neurological trauma/disease. Changes in the nervous systems of these patients alter bladder control, and neuroimaging may become a valuable tool for assessing these alterations.


Assuntos
Doenças do Sistema Nervoso/complicações , Neuroimagem , Doenças Urológicas/diagnóstico por imagem , Doenças Urológicas/etiologia , Humanos
15.
J Neurotrauma ; 37(6): 860-867, 2020 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-31544628

RESUMO

This study aimed to compare macrostructural and microstructural neurodegenerative changes remote from a cervical spinal cord injury in traumatic spinal cord injury (tSCI) and degenerative cervical myelopathy (DCM) patients using quantitative magnetic resonance imaging (MRI). Twenty-nine tSCI patients, 20 mild/moderate DCM patients, and 22 healthy controls underwent a high-resolution MRI protocol at the cervical cord (C2/C3). High-resolution T2*-weighted and diffusion-weighted scans provided data to calculate tissue-specific cross-sectional areas of the spinal cord and tract-specific diffusion indices of cord white matter, respectively. Regression analysis determined associations between neurodegeneration and clinical impairment. tSCI patients showed more impairment in upper limb strength and manual dexterity when compared with DCM patients. While macrostructural MRI measures revealed a similar extent of remote cord atrophy at cervical level, microstructural measures (diffusion indices) were able to distinguish more pronounced tract-specific neurodegeneration in tSCI patients when compared with DCM patients. Tract-specific neurodegeneration was associated with upper limb impairment. Despite clinical differences between severely impaired tSCI compared with mildly affected DCM patient, extensive cord atrophy is present remotely from the focal spinal cord injury. Diffusion indices revealed greater tract-specific alterations in tSCI patients. Therefore, diffusion indices are more sensitive than macrostructural MRI measures as these are able to distinguish between traumatic and non-traumatic spinal cord injury. Neuroimaging biomarkers of cervical cord integrity hold potential as predictors of recovery and might be suitable biomarkers for interventional trials both in traumatic and non-traumatic SCI.


Assuntos
Medula Cervical/diagnóstico por imagem , Medula Cervical/metabolismo , Doenças Neurodegenerativas/diagnóstico por imagem , Doenças Neurodegenerativas/metabolismo , Traumatismos da Medula Espinal/diagnóstico por imagem , Traumatismos da Medula Espinal/metabolismo , Adulto , Idoso , Biomarcadores/metabolismo , Medula Cervical/lesões , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade
16.
Lancet Neurol ; 18(12): 1123-1135, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31405713

RESUMO

Traumatic spinal cord injury occurs when an external physical impact damages the spinal cord and leads to permanent neurological dysfunction and disability, and it is associated with a high socioeconomic burden. Conventional MRI plays a crucial role in the diagnostic workup as it reveals extrinsic compression of the spinal cord and disruption of the discoligamentous complex. Additionally, it can reveal macrostructural evidence of primary intramedullary damage such as haemorrhage, oedema, post-traumatic cystic cavities, and tissue bridges. Quantitative MRI, such as magnetisation transfer, magnetic resonance relaxation mapping, and diffusion imaging, enables the tracking of secondary changes across the neuraxis at the microstructural level. Both conventional MRI and quantitative MRI metrics, obtained early after spinal cord injury, are predictive of clinical outcome. Thus, neuroimaging biomarkers could serve as surrogate endpoints for more efficient future trials targeting acute and chronic spinal cord injury. The adoption of neuroimaging biomarkers in centres for spinal cord injury might lead to personalised patient care.


Assuntos
Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Traumatismos da Medula Espinal/diagnóstico por imagem , Medula Espinal/diagnóstico por imagem , Encéfalo/fisiopatologia , Humanos , Medula Espinal/fisiopatologia , Traumatismos da Medula Espinal/fisiopatologia
17.
Spinal Cord ; 57(9): 717-728, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31267015

RESUMO

Traumatic spinal cord injury (SCI) leads to immediate neuronal and axonal damage at the focal injury site and triggers secondary pathologic series of events resulting in sensorimotor and autonomic dysfunction below the level of injury. Although there is no cure for SCI, neuroprotective and regenerative therapies show promising results at the preclinical stage. There is a pressing need to develop non-invasive outcome measures that can indicate whether a candidate therapeutic agent or a cocktail of therapeutic agents are positively altering the underlying disease processes. Recent conventional MRI studies have quantified spinal cord lesion characteristics and elucidated their relationship between severity of injury to clinical impairment and recovery. Next to the quantification of the primary cord damage, quantitative MRI measures of spinal cord (rostrocaudally to the lesion site) and brain integrity have demonstrated progressive and specific neurodegeneration of afferent and efferent neuronal pathways. MRI could therefore play a key role to ultimately uncover the relationship between clinical impairment/recovery and injury-induced neurodegenerative changes in the spinal cord and brain. Moreover, neuroimaging biomarkers hold promises to improve clinical trial design and efficiency through better patient stratification. The purpose of this narrative review is therefore to propose a guideline of clinically available MRI sequences and their derived neuroimaging biomarkers that have the potential to assess tissue damage at the macro- and microstructural level after SCI. In this piece, we make a recommendation for the use of key MRI sequences-both conventional and advanced-for clinical work-up and clinical trials.


Assuntos
Encéfalo/diagnóstico por imagem , Ensaios Clínicos como Assunto/normas , Imageamento por Ressonância Magnética/normas , Guias de Prática Clínica como Assunto/normas , Traumatismos da Medula Espinal/diagnóstico por imagem , Ensaios Clínicos como Assunto/métodos , Humanos , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Neuroimagem/normas , Traumatismos da Medula Espinal/epidemiologia
18.
Data Brief ; 25: 104132, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31297422

RESUMO

The hMRI toolbox is an open-source toolbox for the calculation of quantitative MRI parameter maps from a series of weighted imaging data, and optionally additional calibration data. The multi-parameter mapping (MPM) protocol, incorporating calibration data to correct for spatial variation in the scanner's transmit and receive fields, is the most complete protocol that can be handled by the toolbox. Here we present a dataset acquired with such a full MPM protocol, which is made freely available to be used as a tutorial by following instructions provided on the associated toolbox wiki pages, which can be found at http://hMRI.info, and following the theory described in: hMRI - A toolbox for quantitative MRI in neuroscience and clinical research [1].

19.
Neurology ; 92(12): e1367-e1377, 2019 03 19.
Artigo em Inglês | MEDLINE | ID: mdl-30770423

RESUMO

OBJECTIVE: To characterize remote secondary neurodegeneration of spinal tracts and neurons below a cervical spinal cord injury (SCI) and its relation to the severity of injury, the integrity of efferent and afferent pathways, and clinical impairment. METHODS: A comprehensive high-resolution MRI protocol was acquired in 17 traumatic cervical SCI patients and 14 controls at 3T. At the cervical lesion, a sagittal T2-weighted scan provided information on the width of preserved midsagittal tissue bridges. In the lumbar enlargement, high-resolution T2*-weighted and diffusion-weighted scans were used to calculate tissue-specific cross-sectional areas and diffusion indices, respectively. Regression analyses determined associations between MRI readouts and the electrophysiologic and clinical measures. RESULTS: At the cervical injury level, preserved midsagittal tissue bridges were present in the majority of patients. In the lumbar enlargement, neurodegeneration-in terms of macrostructural and microstructural MRI changes-was evident in the white matter and ventral and dorsal horns. Patients with thinner midsagittal tissue bridges had smaller ventral horn area, higher radial diffusivity in the gray matter, smaller motor evoked potential amplitude from the lower extremities, and lower motor score. In addition, smaller width of midsagittal tissue bridges was also associated with smaller tibialis sensory evoked potential amplitude and lower light-touch score. CONCLUSIONS: This study shows extensive tissue-specific cord pathology in infralesional spinal networks following cervical SCI, its magnitude relating to lesion severity, electrophysiologic integrity, and clinical impairment of the lower extremity. The clinical eloquence of remote neurodegenerative changes speaks to the application of neuroimaging biomarkers in diagnostic workup and planning of clinical trials.


Assuntos
Medula Cervical/lesões , Doenças Neurodegenerativas/diagnóstico por imagem , Doenças Neurodegenerativas/etiologia , Traumatismos da Medula Espinal/complicações , Traumatismos da Medula Espinal/diagnóstico por imagem , Adulto , Idoso , Estudos Transversais , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Vértebras Lombares , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Doenças Neurodegenerativas/fisiopatologia , Traumatismos da Medula Espinal/fisiopatologia , Adulto Jovem
20.
Neuroimage ; 194: 191-210, 2019 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-30677501

RESUMO

Neuroscience and clinical researchers are increasingly interested in quantitative magnetic resonance imaging (qMRI) due to its sensitivity to micro-structural properties of brain tissue such as axon, myelin, iron and water concentration. We introduce the hMRI-toolbox, an open-source, easy-to-use tool available on GitHub, for qMRI data handling and processing, presented together with a tutorial and example dataset. This toolbox allows the estimation of high-quality multi-parameter qMRI maps (longitudinal and effective transverse relaxation rates R1 and R2⋆, proton density PD and magnetisation transfer MT saturation) that can be used for quantitative parameter analysis and accurate delineation of subcortical brain structures. The qMRI maps generated by the toolbox are key input parameters for biophysical models designed to estimate tissue microstructure properties such as the MR g-ratio and to derive standard and novel MRI biomarkers. Thus, the current version of the toolbox is a first step towards in vivo histology using MRI (hMRI) and is being extended further in this direction. Embedded in the Statistical Parametric Mapping (SPM) framework, it benefits from the extensive range of established SPM tools for high-accuracy spatial registration and statistical inferences and can be readily combined with existing SPM toolboxes for estimating diffusion MRI parameter maps. From a user's perspective, the hMRI-toolbox is an efficient, robust and simple framework for investigating qMRI data in neuroscience and clinical research.


Assuntos
Mapeamento Encefálico/métodos , Conjuntos de Dados como Assunto , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Neurociências/métodos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...